This opportunity was published by HEALTH & SAFETY EXECUTIVE. Unless specified, BECBC will not be able to provide any additional information for interested tenderers.
The information listed on this site is based on information sent to us by member companies. We advise anyone planning to submit a tender to check all details with the purchaser. BECBC cannot guarantee that the details and deadlines listed here are correct.
Buying Organisation | HEALTH & SAFETY EXECUTIVE |
---|---|
Opportunity Type | Private Sector |
Opportunity Method | Contract Opportunity |
Notice Type | Notice |
Nature of Opportunity | Works |
Contract Description: | Specification - We need two compressors installing in separate locations, both to be installed in containers serviced with 3 phase power and heating. The footprint of each compressor should not exceed 800 x 1800 mm. Both compressors need to have desiccant dryers to minus 40PdP and filtration to 0.1 micron with oil separation and drain. Both compressors to have 270 litre air receivers. One compressor must be capable of delivering 7 cft pulse every 10 seconds at 5-7 bar (not exceeding 12 kW motor), and the other must be able to deliver 3.5 cft every 10 seconds (not exceeding 8 kW motor), for up to an hour at a time. |
Website | Visit Website |
Response Deadline | 07-10-20 00:00 |